INSTALLER’S GUIDE
Page 25
9. BURNER & SUPPLY PIPE
INSTALLATION
9.1 Fitting the Burner
1. Place the burner module into the hotbox.
2. Refit the burner cover by lowering it onto the
burner module. The front edge of the burner cover
should locate in front of the burner module. The
sides of the burner cover should locate behind the
front of the burner module. Secure with two screws
removed previously (See figure 22)
3. Refit the Inner Reflector into the hotbox. Be
careful not to scratch the top surface of the burner
cover. Secure using six screws removed previously.
4. Refit the spillage plate. Secure using the four
screws removed previously.
9.2 Supply pipe installation
A nut and olive is provided for an 8mm-pipe inlet
connection directly to the gas control. The isolating
elbow can be rotated to allow a connection from any
direction. The elbow includes a valve for isolating
the gas supply.
The supply pipe must be rigid material. Flexible
pipe must not be used. Connect the supply line to the appliance.
Pressure check the installation pipework for gas soundness in accordance with the current
edition of BS6891.
Concealed Supply Pipe Connection
If a concealed connection from inside the fireplace is required then, before the
appliance is fitted into the fireplace it will be necessary to extend the supply line so
that it will project through the chosen removable circular panel at the back of the hotbox
and run to the elbow at the front. The pipe run from the supply line up to the rear opening
in the hotbox must be kept away from the area which will be taken by the hotbox when it
is installed (See figure 7).
Note that the centre of the appliance inlet elbow is 25mm above the fireplace floor.
Figure 22 Burner cover location