INSTALLER’S GUIDE
Page 11
4.14 An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be installed
unless the fan is permanently disconnected.
4.15 In the United Kingdom (GB) no special ventilation bricks or vents are
normally required in the room for this appliance. In the Republic of Ireland (IE)
permanent ventilation must comply with the regulations currently in force.
4.16 Propane gas appliances
must not be installed in a
room that is built entirely
below ground level (See BS
5871 Part 2).
4.17 If the appliance is to be
fitted against a wall with
combustible cladding, the
cladding must be removed
from the area covered by the
outer surround. The cladding
must also not touch the
surround. (See figure 4). We
suggest that the actual
surround is used as a
template to mark the area for
combustible cladding removal and that this area is increased by at least 2mm all round. If
the cladding projects forward from the fixing plane of the fire the clearance at the top of
the appliance must be increased to a minimum 15mm.This will allow for surround
removal.
4.18 Proprietary terminals must comply with BS 715 or BS 1289. Any terminal or
termination must be positioned in accordance with BS 5440 Part 1 to ensure that the
products of combustion can be safely dispersed into the outside atmosphere. Where the
appliance is connected to an unlined brick chimney it is generally unnecessary for the
chimney pot to be replaced or for a terminal to be fitted unless the flue has a diameter
smaller than 170mm.
Figure 4. Removal of combustible cladding